Filter Results By:

Products

Applications

Manufacturers

Showing results: 7486 - 7500 of 17041 items found.

  • Reservoir Isolators

    Parker Hannifin Corp.

    Fluid contamination can lead to high maintenance costs and downtime in hydraulic systems. Parker reservoir isolators provide protection against the ingestion of airborne contaminants such as dust, chemicals and water vapor through the breather-vent of your hydraulic system. Utilizing an elastomer bladder as a lung, the changes in gas volume in a hydraulic system's reservoir can be trapped and prevented from mixing with the outside atmosphere. Unlike conventional breather-vent filters, Parker reservoir isolators provide a positive separation without the possibility of clogging or need for maintenance.

  • CT / PT Analyzer

    CTPTA-504 - UDEYRAJ ELECTRICALS PRIVATE LIMITED

    UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.

  • Data Collection

    Davis Instruments Corp.

    Data collection is the heart and soul of weather monitoring and prediction. Weather station data collection can use either wired or wireless systems, and Davis Instruments has a range of transmitters, receivers, and data access options to help you transmit data to your personal system or larger groups. You can upload data only to your Vantage Pro2 or Vantage Vue console, or you can choose to also upload to WeatherLink.com where your data can be accessed on your phone or computer.

  • Hipot Testers

    Hypot® Series - Associated Research

    The Hypot Series sets the standard for safety and efficiency in production line Hipot Testing. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot Series provides innovations that will allow you to begin achieving best practices for safety and efficiency without the need for an expensive automated test system or connection to a PC. You can even connect the Hypot Series with the HYAMP Series to form a seamless safety compliance system for Hipot and Ground Bond Testing.

  • NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module

    783367-01 - NI

    51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    780968-01 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    780968-02 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    785041-01 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.

  • PCI-8361, PCI Host, 100 MB/s, Copper Cable MXI-Express Device for PXI Remote Control

    781394-01 - NI

    The PCI‑8361 is an MXI‑Express remote controller for devices or systems over cabled PCI from a computer with a PCI slot. The PCI‑8361 card provides a PCI link over a copper cable to the PXI‑8360 remote control module when used for PXI system control. This link is transparent to software applications and drivers, so computers and servers can control connected devices with no additional programming. With NI remote controllers, PXI modules can be used as if they are PCI devices directly installed in the computer.

  • NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module

    783362-01 - NI

    51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.

  • PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module

    782835-37 - NI

    256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module

    782835-38 - NI

    256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • PXIe-2739 , 256-Crosspoint, 16x16, 2-Wire PXI Matrix Switch Module

    782835-39 - NI

    256-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2739 is a high‐density 16x16 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • Multi-Wavelength Meter

    86122C - Keysight Technologies

    With an absolute wavelength accuracy of 0.2 ppm and 0.15 ppm differential accuracy, the new Keysight 86122C Multi-Wavelength Meter belongs in the top class of wavelength meters available for optical communication testing. Its wavelength range of 1270 to 1650 nm covers all fiber-to-the-home, metro and long-haul transmission systems. The instrument can measure the spectra of up to 1,000 laser lines at once, which is more than sufficient for fully populated dense-wavelength-division multiplexed systems (DWDM).

  • Laser Heads

    Keysight Technologies

    The laser head is the source of the laser beam used in all laser motion and position measurement systems. The primary difference between laser heads is in the velocity, reference frequency and optical output power. Other considerations are size, heat dissipation, and input power requirements. Which laser you choose depends primarily on the application in which it will be used. For example, semiconductor lithography systems typically have faster moving parts (stages), and therefore need higher velocities than machine tool applications.

Get Help